{"title":"XS10 Circular Connectors","description":"\u003cp\u003eXS10 panel-to-cable and cable-to-cable matching connector sets. Each contact count is a separate product.\u003c\/p\u003e","products":[{"product_id":"xs10-2-connector-set","title":"2-Pin XS10 Panel \u0026 Cable Push-Pull Connector Set","description":"\u003cdiv class=\"pevxi-story\"\u003e\n\u003cnav class=\"pevxi-story-nav\"\u003e\u003ca href=\"#pevxi-applications\"\u003eApplications\u003c\/a\u003e\u003ca href=\"#pevxi-size\"\u003eSpecifications\u003c\/a\u003e\u003ca href=\"#pevxi-workflow\"\u003eInstallation\u003c\/a\u003e\u003ca href=\"#pevxi-bulk\"\u003eQuick order\u003c\/a\u003e\u003c\/nav\u003e\u003csection id=\"pevxi-applications\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-167af10cc19552-04-application.jpg?v=1794240369\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-2 04-application\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e2-Pin XS10 Panel \u0026amp; Cable Push-Pull Connector Set\u003c\/h2\u003e\n\u003cp\u003eOne complete matching male and female set, fixed at 2 contacts. Includes a male panel receptacle and a female cable connector.\u003c\/p\u003e\n\u003cp\u003eFor instrument wiring, serviceable equipment leads and compact test fixtures. Match contact count, mounting structure, alignment key and circuit assignment before connecting.\u003c\/p\u003e\n\u003cp\u003eChoose 1, 5 or 20 sets per pack. Other contact counts and mounting styles are separate products.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"pevxi-size\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\n\u003ch2\u003eInterface \u0026amp; specifications\u003c\/h2\u003e\n\u003ctable class=\"pevxi-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eXS10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContact count\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003ctd\u003ePanel-to-cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTermination\u003c\/th\u003e\n\u003ctd\u003eIntegral solder contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal interface\u003c\/th\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier reference outline\u003c\/th\u003e\n\u003ctd\u003e31.5 mm body section; 9.5 mm panel projection; M10 mounting thread. See the original outline for measurement boundaries.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier rating reference\u003c\/th\u003e\n\u003ctd\u003e3 A \/ 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier test voltage reference\u003c\/th\u003e\n\u003ctd\u003e2000 V AC \/ 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier insulation resistance\u003c\/th\u003e\n\u003ctd\u003eAt least 1000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier contact resistance\u003c\/th\u003e\n\u003ctd\u003eAt most 0.005 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSupplier reference values are connector data, not a certification of the complete equipment or a wired assembly.\u003c\/p\u003e\n\u003ch3\u003eModel \u0026amp; Reference Codes\u003c\/h3\u003e\n\u003ctable class=\"pevxi-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSet SKU\u003c\/th\u003e\n\u003ctd\u003eXS10-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMale half\u003c\/th\u003e\n\u003ctd\u003eXS10-2-M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFemale half\u003c\/th\u003e\n\u003ctd\u003eXS10-2-F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-ec57f9a2c1f6ec-02-size.jpg?v=1794238439\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-2 02-size\"\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"pevxi-workflow\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-7b38cd24afdb4d-05-operation.jpg?v=1794240728\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-2 05-operation\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003ePrepare. Solder. Inspect.\u003c\/h2\u003e\n\u003cp\u003eWork on de-energized circuits. Slide the cable housing and fastening parts onto the cable before termination. Solder the conductors to their assigned contacts and insulate the joints.\u003c\/p\u003e\n\u003cp\u003eRefit the housing and cable fastening parts. Align the key, mate fully and inspect retention, continuity and isolation before service. Wire color alone does not establish the circuit assignment.\u003c\/p\u003e\n\u003ch3\u003eIncluded in each set\u003c\/h3\u003e\n\u003cp\u003eOne male half and one matching female half, with integral contacts and the pictured fastening parts. No loose crimp terminals, cable, solder, tools or equipment are supplied.\u003c\/p\u003e\n\u003ch3\u003eComplete your matching parts\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"\/collections\/xs10-family\"\u003eBrowse XS10 connector sets by mounting style and contact count\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003c\/div\u003e\u003cdiv class=\"pevxi-order-heading\" id=\"pevxi-bulk\"\u003e\n\u003ch2\u003eBuild your order, pack by pack.\u003c\/h2\u003e\n\u003cp\u003eEvery row below is the same 2-pin panel-to-cable set. The selected pack contains 1, 5 or 20 complete sets; quantity counts packs.\u003c\/p\u003e\n\u003cp\u003eShips from China · Preparation 5–7 calendar days. \u003ca href=\"\/policies\/shipping-policy\"\u003eShipping details\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"PEVXI","offers":[{"title":"1 Set","offer_id":50983655506178,"sku":"XS10-2-1","price":5.6,"currency_code":"USD","in_stock":true},{"title":"5 Sets - Save 5%","offer_id":50983655538946,"sku":"XS10-2-5","price":26.6,"currency_code":"USD","in_stock":true},{"title":"20 Sets - Save 10%","offer_id":50983655571714,"sku":"XS10-2-20","price":100.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-248c42dd22c9c8-01-hero.jpg?v=1794265914"},{"product_id":"xs10-2-d-connector-set","title":"2-Pin XS10 Cable-to-Cable Push-Pull Connector Set","description":"\u003cdiv class=\"pevxi-story\"\u003e\n\u003cnav class=\"pevxi-story-nav\"\u003e\u003ca href=\"#pevxi-applications\"\u003eApplications\u003c\/a\u003e\u003ca href=\"#pevxi-size\"\u003eSpecifications\u003c\/a\u003e\u003ca href=\"#pevxi-workflow\"\u003eInstallation\u003c\/a\u003e\u003ca href=\"#pevxi-bulk\"\u003eQuick order\u003c\/a\u003e\u003c\/nav\u003e\u003csection id=\"pevxi-applications\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-0558bd2d55c8d2-04-application.jpg?v=1794240378\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-2-D 04-application\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e2-Pin XS10 Cable-to-Cable Push-Pull Connector Set\u003c\/h2\u003e\n\u003cp\u003eOne complete matching male and female set, fixed at 2 contacts. Both halves are cable connectors for an inline cable connection.\u003c\/p\u003e\n\u003cp\u003eFor instrument wiring, serviceable equipment leads and compact test fixtures. Match contact count, mounting structure, alignment key and circuit assignment before connecting.\u003c\/p\u003e\n\u003cp\u003eChoose 1, 5 or 20 sets per pack. Other contact counts and mounting styles are separate products.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"pevxi-size\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\n\u003ch2\u003eInterface \u0026amp; specifications\u003c\/h2\u003e\n\u003ctable class=\"pevxi-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eXS10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContact count\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003ctd\u003eCable-to-cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTermination\u003c\/th\u003e\n\u003ctd\u003eIntegral solder contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal interface\u003c\/th\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier rating reference\u003c\/th\u003e\n\u003ctd\u003e3 A \/ 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier test voltage reference\u003c\/th\u003e\n\u003ctd\u003e2000 V AC \/ 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier insulation resistance\u003c\/th\u003e\n\u003ctd\u003eAt least 1000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier contact resistance\u003c\/th\u003e\n\u003ctd\u003eAt most 0.005 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSupplier reference values are connector data, not a certification of the complete equipment or a wired assembly.\u003c\/p\u003e\n\u003ch3\u003eModel \u0026amp; Reference Codes\u003c\/h3\u003e\n\u003ctable class=\"pevxi-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSet SKU\u003c\/th\u003e\n\u003ctd\u003eXS10-2-D-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMale half\u003c\/th\u003e\n\u003ctd\u003eXS10-2-M-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFemale half\u003c\/th\u003e\n\u003ctd\u003eXS10-2-F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-802991f172241c-02-size.jpg?v=1794238452\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-2-D 02-size\"\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"pevxi-workflow\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-7e048817c2ef8d-05-operation.jpg?v=1794240736\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-2-D 05-operation\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003ePrepare. Solder. Inspect.\u003c\/h2\u003e\n\u003cp\u003eWork on de-energized circuits. Slide the cable housing and fastening parts onto the cable before termination. Solder the conductors to their assigned contacts and insulate the joints.\u003c\/p\u003e\n\u003cp\u003eRefit the housing and cable fastening parts. Align the key, mate fully and inspect retention, continuity and isolation before service. Wire color alone does not establish the circuit assignment.\u003c\/p\u003e\n\u003ch3\u003eIncluded in each set\u003c\/h3\u003e\n\u003cp\u003eOne male half and one matching female half, with integral contacts and the pictured fastening parts. No loose crimp terminals, cable, solder, tools or equipment are supplied.\u003c\/p\u003e\n\u003ch3\u003eComplete your matching parts\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"\/collections\/xs10-family\"\u003eBrowse XS10 connector sets by mounting style and contact count\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003c\/div\u003e\u003cdiv class=\"pevxi-order-heading\" id=\"pevxi-bulk\"\u003e\n\u003ch2\u003eBuild your order, pack by pack.\u003c\/h2\u003e\n\u003cp\u003eEvery row below is the same 2-pin cable-to-cable set. The selected pack contains 1, 5 or 20 complete sets; quantity counts packs.\u003c\/p\u003e\n\u003cp\u003eShips from China · Preparation 5–7 calendar days. \u003ca href=\"\/policies\/shipping-policy\"\u003eShipping details\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"PEVXI","offers":[{"title":"1 Set","offer_id":50983655768322,"sku":"XS10-2-D-1","price":7.0,"currency_code":"USD","in_stock":true},{"title":"5 Sets - Save 5%","offer_id":50983655801090,"sku":"XS10-2-D-5","price":33.25,"currency_code":"USD","in_stock":true},{"title":"20 Sets - Save 10%","offer_id":50983655833858,"sku":"XS10-2-D-20","price":126.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-51765f5925dca5-01-hero.jpg?v=1794265921"},{"product_id":"xs10-3-connector-set","title":"3-Pin XS10 Panel \u0026 Cable Push-Pull Connector Set","description":"\u003cdiv class=\"pevxi-story\"\u003e\n\u003cnav class=\"pevxi-story-nav\"\u003e\u003ca href=\"#pevxi-applications\"\u003eApplications\u003c\/a\u003e\u003ca href=\"#pevxi-size\"\u003eSpecifications\u003c\/a\u003e\u003ca href=\"#pevxi-workflow\"\u003eInstallation\u003c\/a\u003e\u003ca href=\"#pevxi-bulk\"\u003eQuick order\u003c\/a\u003e\u003c\/nav\u003e\u003csection id=\"pevxi-applications\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-5661537daed305-04-application.jpg?v=1794240367\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-3 04-application\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e3-Pin XS10 Panel \u0026amp; Cable Push-Pull Connector Set\u003c\/h2\u003e\n\u003cp\u003eOne complete matching male and female set, fixed at 3 contacts. Includes a male panel receptacle and a female cable connector.\u003c\/p\u003e\n\u003cp\u003eFor instrument wiring, serviceable equipment leads and compact test fixtures. Match contact count, mounting structure, alignment key and circuit assignment before connecting.\u003c\/p\u003e\n\u003cp\u003eChoose 1, 5 or 20 sets per pack. Other contact counts and mounting styles are separate products.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"pevxi-size\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\n\u003ch2\u003eInterface \u0026amp; specifications\u003c\/h2\u003e\n\u003ctable class=\"pevxi-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eXS10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContact count\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003ctd\u003ePanel-to-cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTermination\u003c\/th\u003e\n\u003ctd\u003eIntegral solder contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal interface\u003c\/th\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier reference outline\u003c\/th\u003e\n\u003ctd\u003e31.5 mm body section; 9.5 mm panel projection; M10 mounting thread. See the original outline for measurement boundaries.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier rating reference\u003c\/th\u003e\n\u003ctd\u003e3 A \/ 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier test voltage reference\u003c\/th\u003e\n\u003ctd\u003e2000 V AC \/ 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier insulation resistance\u003c\/th\u003e\n\u003ctd\u003eAt least 1000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier contact resistance\u003c\/th\u003e\n\u003ctd\u003eAt most 0.005 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSupplier reference values are connector data, not a certification of the complete equipment or a wired assembly.\u003c\/p\u003e\n\u003ch3\u003eModel \u0026amp; Reference Codes\u003c\/h3\u003e\n\u003ctable class=\"pevxi-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSet SKU\u003c\/th\u003e\n\u003ctd\u003eXS10-3-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMale half\u003c\/th\u003e\n\u003ctd\u003eXS10-3-M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFemale half\u003c\/th\u003e\n\u003ctd\u003eXS10-3-F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-80f673f947d1a9-02-size.jpg?v=1794238438\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-3 02-size\"\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"pevxi-workflow\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-8e3c2be9bc401d-05-operation.jpg?v=1794240727\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-3 05-operation\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003ePrepare. Solder. Inspect.\u003c\/h2\u003e\n\u003cp\u003eWork on de-energized circuits. Slide the cable housing and fastening parts onto the cable before termination. Solder the conductors to their assigned contacts and insulate the joints.\u003c\/p\u003e\n\u003cp\u003eRefit the housing and cable fastening parts. Align the key, mate fully and inspect retention, continuity and isolation before service. Wire color alone does not establish the circuit assignment.\u003c\/p\u003e\n\u003ch3\u003eIncluded in each set\u003c\/h3\u003e\n\u003cp\u003eOne male half and one matching female half, with integral contacts and the pictured fastening parts. No loose crimp terminals, cable, solder, tools or equipment are supplied.\u003c\/p\u003e\n\u003ch3\u003eComplete your matching parts\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"\/collections\/xs10-family\"\u003eBrowse XS10 connector sets by mounting style and contact count\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003c\/div\u003e\u003cdiv class=\"pevxi-order-heading\" id=\"pevxi-bulk\"\u003e\n\u003ch2\u003eBuild your order, pack by pack.\u003c\/h2\u003e\n\u003cp\u003eEvery row below is the same 3-pin panel-to-cable set. The selected pack contains 1, 5 or 20 complete sets; quantity counts packs.\u003c\/p\u003e\n\u003cp\u003eShips from China · Preparation 5–7 calendar days. \u003ca href=\"\/policies\/shipping-policy\"\u003eShipping details\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"PEVXI","offers":[{"title":"1 Set","offer_id":50983656292610,"sku":"XS10-3-1","price":5.6,"currency_code":"USD","in_stock":true},{"title":"5 Sets - Save 5%","offer_id":50983656325378,"sku":"XS10-3-5","price":26.6,"currency_code":"USD","in_stock":true},{"title":"20 Sets - Save 10%","offer_id":50983656358146,"sku":"XS10-3-20","price":100.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-50ccf914e8e573-01-hero.jpg?v=1794265928"},{"product_id":"xs10-3-d-connector-set","title":"3-Pin XS10 Cable-to-Cable Push-Pull Connector Set","description":"\u003cdiv class=\"pevxi-story\"\u003e\n\u003cnav class=\"pevxi-story-nav\"\u003e\u003ca href=\"#pevxi-applications\"\u003eApplications\u003c\/a\u003e\u003ca href=\"#pevxi-size\"\u003eSpecifications\u003c\/a\u003e\u003ca href=\"#pevxi-workflow\"\u003eInstallation\u003c\/a\u003e\u003ca href=\"#pevxi-bulk\"\u003eQuick order\u003c\/a\u003e\u003c\/nav\u003e\u003csection id=\"pevxi-applications\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-8af51b858dc0be-04-application.jpg?v=1794240377\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-3-D 04-application\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e3-Pin XS10 Cable-to-Cable Push-Pull Connector Set\u003c\/h2\u003e\n\u003cp\u003eOne complete matching male and female set, fixed at 3 contacts. Both halves are cable connectors for an inline cable connection.\u003c\/p\u003e\n\u003cp\u003eFor instrument wiring, serviceable equipment leads and compact test fixtures. Match contact count, mounting structure, alignment key and circuit assignment before connecting.\u003c\/p\u003e\n\u003cp\u003eChoose 1, 5 or 20 sets per pack. Other contact counts and mounting styles are separate products.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"pevxi-size\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\n\u003ch2\u003eInterface \u0026amp; specifications\u003c\/h2\u003e\n\u003ctable class=\"pevxi-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eXS10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContact count\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003ctd\u003eCable-to-cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTermination\u003c\/th\u003e\n\u003ctd\u003eIntegral solder contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal interface\u003c\/th\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier rating reference\u003c\/th\u003e\n\u003ctd\u003e3 A \/ 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier test voltage reference\u003c\/th\u003e\n\u003ctd\u003e2000 V AC \/ 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier insulation resistance\u003c\/th\u003e\n\u003ctd\u003eAt least 1000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier contact resistance\u003c\/th\u003e\n\u003ctd\u003eAt most 0.005 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSupplier reference values are connector data, not a certification of the complete equipment or a wired assembly.\u003c\/p\u003e\n\u003ch3\u003eModel \u0026amp; Reference Codes\u003c\/h3\u003e\n\u003ctable class=\"pevxi-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSet SKU\u003c\/th\u003e\n\u003ctd\u003eXS10-3-D-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMale half\u003c\/th\u003e\n\u003ctd\u003eXS10-3-M-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFemale half\u003c\/th\u003e\n\u003ctd\u003eXS10-3-F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-b31dcabe1e7e54-02-size.jpg?v=1794238455\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-3-D 02-size\"\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"pevxi-workflow\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-683a7345b0262c-05-operation.jpg?v=1794240735\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-3-D 05-operation\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003ePrepare. Solder. Inspect.\u003c\/h2\u003e\n\u003cp\u003eWork on de-energized circuits. Slide the cable housing and fastening parts onto the cable before termination. Solder the conductors to their assigned contacts and insulate the joints.\u003c\/p\u003e\n\u003cp\u003eRefit the housing and cable fastening parts. Align the key, mate fully and inspect retention, continuity and isolation before service. Wire color alone does not establish the circuit assignment.\u003c\/p\u003e\n\u003ch3\u003eIncluded in each set\u003c\/h3\u003e\n\u003cp\u003eOne male half and one matching female half, with integral contacts and the pictured fastening parts. No loose crimp terminals, cable, solder, tools or equipment are supplied.\u003c\/p\u003e\n\u003ch3\u003eComplete your matching parts\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"\/collections\/xs10-family\"\u003eBrowse XS10 connector sets by mounting style and contact count\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003c\/div\u003e\u003cdiv class=\"pevxi-order-heading\" id=\"pevxi-bulk\"\u003e\n\u003ch2\u003eBuild your order, pack by pack.\u003c\/h2\u003e\n\u003cp\u003eEvery row below is the same 3-pin cable-to-cable set. The selected pack contains 1, 5 or 20 complete sets; quantity counts packs.\u003c\/p\u003e\n\u003cp\u003eShips from China · Preparation 5–7 calendar days. \u003ca href=\"\/policies\/shipping-policy\"\u003eShipping details\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"PEVXI","offers":[{"title":"1 Set","offer_id":50983656816898,"sku":"XS10-3-D-1","price":7.0,"currency_code":"USD","in_stock":true},{"title":"5 Sets - Save 5%","offer_id":50983656849666,"sku":"XS10-3-D-5","price":33.25,"currency_code":"USD","in_stock":true},{"title":"20 Sets - Save 10%","offer_id":50983656882434,"sku":"XS10-3-D-20","price":126.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-9507bba2a699b4-01-hero.jpg?v=1794265935"},{"product_id":"xs10-4-connector-set","title":"4-Pin XS10 Panel \u0026 Cable Push-Pull Connector Set","description":"\u003cdiv class=\"pevxi-story\"\u003e\n\u003cnav class=\"pevxi-story-nav\"\u003e\u003ca href=\"#pevxi-applications\"\u003eApplications\u003c\/a\u003e\u003ca href=\"#pevxi-size\"\u003eSpecifications\u003c\/a\u003e\u003ca href=\"#pevxi-workflow\"\u003eInstallation\u003c\/a\u003e\u003ca href=\"#pevxi-bulk\"\u003eQuick order\u003c\/a\u003e\u003c\/nav\u003e\u003csection id=\"pevxi-applications\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-17bafaf7dd90b7-04-application.jpg?v=1794240368\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-4 04-application\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e4-Pin XS10 Panel \u0026amp; Cable Push-Pull Connector Set\u003c\/h2\u003e\n\u003cp\u003eOne complete matching male and female set, fixed at 4 contacts. Includes a male panel receptacle and a female cable connector.\u003c\/p\u003e\n\u003cp\u003eFor instrument wiring, serviceable equipment leads and compact test fixtures. Match contact count, mounting structure, alignment key and circuit assignment before connecting.\u003c\/p\u003e\n\u003cp\u003eChoose 1, 5 or 20 sets per pack. Other contact counts and mounting styles are separate products.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"pevxi-size\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\n\u003ch2\u003eInterface \u0026amp; specifications\u003c\/h2\u003e\n\u003ctable class=\"pevxi-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eXS10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContact count\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003ctd\u003ePanel-to-cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTermination\u003c\/th\u003e\n\u003ctd\u003eIntegral solder contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal interface\u003c\/th\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier reference outline\u003c\/th\u003e\n\u003ctd\u003e31.5 mm body section; 9.5 mm panel projection; M10 mounting thread. See the original outline for measurement boundaries.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier rating reference\u003c\/th\u003e\n\u003ctd\u003e3 A \/ 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier test voltage reference\u003c\/th\u003e\n\u003ctd\u003e2000 V AC \/ 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier insulation resistance\u003c\/th\u003e\n\u003ctd\u003eAt least 1000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier contact resistance\u003c\/th\u003e\n\u003ctd\u003eAt most 0.005 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSupplier reference values are connector data, not a certification of the complete equipment or a wired assembly.\u003c\/p\u003e\n\u003ch3\u003eModel \u0026amp; Reference Codes\u003c\/h3\u003e\n\u003ctable class=\"pevxi-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSet SKU\u003c\/th\u003e\n\u003ctd\u003eXS10-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMale half\u003c\/th\u003e\n\u003ctd\u003eXS10-4-M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFemale half\u003c\/th\u003e\n\u003ctd\u003eXS10-4-F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-ea7632ad9f6068-02-size.jpg?v=1794238441\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-4 02-size\"\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"pevxi-workflow\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-b389447da43199-05-operation.jpg?v=1794240725\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-4 05-operation\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003ePrepare. Solder. Inspect.\u003c\/h2\u003e\n\u003cp\u003eWork on de-energized circuits. Slide the cable housing and fastening parts onto the cable before termination. Solder the conductors to their assigned contacts and insulate the joints.\u003c\/p\u003e\n\u003cp\u003eRefit the housing and cable fastening parts. Align the key, mate fully and inspect retention, continuity and isolation before service. Wire color alone does not establish the circuit assignment.\u003c\/p\u003e\n\u003ch3\u003eIncluded in each set\u003c\/h3\u003e\n\u003cp\u003eOne male half and one matching female half, with integral contacts and the pictured fastening parts. No loose crimp terminals, cable, solder, tools or equipment are supplied.\u003c\/p\u003e\n\u003ch3\u003eComplete your matching parts\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"\/collections\/xs10-family\"\u003eBrowse XS10 connector sets by mounting style and contact count\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003c\/div\u003e\u003cdiv class=\"pevxi-order-heading\" id=\"pevxi-bulk\"\u003e\n\u003ch2\u003eBuild your order, pack by pack.\u003c\/h2\u003e\n\u003cp\u003eEvery row below is the same 4-pin panel-to-cable set. The selected pack contains 1, 5 or 20 complete sets; quantity counts packs.\u003c\/p\u003e\n\u003cp\u003eShips from China · Preparation 5–7 calendar days. \u003ca href=\"\/policies\/shipping-policy\"\u003eShipping details\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"PEVXI","offers":[{"title":"1 Set","offer_id":50983657046274,"sku":"XS10-4-1","price":5.6,"currency_code":"USD","in_stock":true},{"title":"5 Sets - Save 5%","offer_id":50983657079042,"sku":"XS10-4-5","price":26.6,"currency_code":"USD","in_stock":true},{"title":"20 Sets - Save 10%","offer_id":50983657111810,"sku":"XS10-4-20","price":100.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-b5107fb470cd9f-01-hero.jpg?v=1794265942"},{"product_id":"xs10-4-d-connector-set","title":"4-Pin XS10 Cable-to-Cable Push-Pull Connector Set","description":"\u003cdiv class=\"pevxi-story\"\u003e\n\u003cnav class=\"pevxi-story-nav\"\u003e\u003ca href=\"#pevxi-applications\"\u003eApplications\u003c\/a\u003e\u003ca href=\"#pevxi-size\"\u003eSpecifications\u003c\/a\u003e\u003ca href=\"#pevxi-workflow\"\u003eInstallation\u003c\/a\u003e\u003ca href=\"#pevxi-bulk\"\u003eQuick order\u003c\/a\u003e\u003c\/nav\u003e\u003csection id=\"pevxi-applications\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-df5b0075f9ad54-04-application.jpg?v=1794240379\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-4-D 04-application\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e4-Pin XS10 Cable-to-Cable Push-Pull Connector Set\u003c\/h2\u003e\n\u003cp\u003eOne complete matching male and female set, fixed at 4 contacts. Both halves are cable connectors for an inline cable connection.\u003c\/p\u003e\n\u003cp\u003eFor instrument wiring, serviceable equipment leads and compact test fixtures. Match contact count, mounting structure, alignment key and circuit assignment before connecting.\u003c\/p\u003e\n\u003cp\u003eChoose 1, 5 or 20 sets per pack. Other contact counts and mounting styles are separate products.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"pevxi-size\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\n\u003ch2\u003eInterface \u0026amp; specifications\u003c\/h2\u003e\n\u003ctable class=\"pevxi-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eXS10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContact count\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003ctd\u003eCable-to-cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTermination\u003c\/th\u003e\n\u003ctd\u003eIntegral solder contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal interface\u003c\/th\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier rating reference\u003c\/th\u003e\n\u003ctd\u003e3 A \/ 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier test voltage reference\u003c\/th\u003e\n\u003ctd\u003e2000 V AC \/ 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier insulation resistance\u003c\/th\u003e\n\u003ctd\u003eAt least 1000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier contact resistance\u003c\/th\u003e\n\u003ctd\u003eAt most 0.005 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSupplier reference values are connector data, not a certification of the complete equipment or a wired assembly.\u003c\/p\u003e\n\u003ch3\u003eModel \u0026amp; Reference Codes\u003c\/h3\u003e\n\u003ctable class=\"pevxi-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSet SKU\u003c\/th\u003e\n\u003ctd\u003eXS10-4-D-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMale half\u003c\/th\u003e\n\u003ctd\u003eXS10-4-M-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFemale half\u003c\/th\u003e\n\u003ctd\u003eXS10-4-F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-ebf484d247ff57-02-size.jpg?v=1794238455\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-4-D 02-size\"\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"pevxi-workflow\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-6631f696bfcfbe-05-operation.jpg?v=1794240737\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-4-D 05-operation\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003ePrepare. Solder. Inspect.\u003c\/h2\u003e\n\u003cp\u003eWork on de-energized circuits. Slide the cable housing and fastening parts onto the cable before termination. Solder the conductors to their assigned contacts and insulate the joints.\u003c\/p\u003e\n\u003cp\u003eRefit the housing and cable fastening parts. Align the key, mate fully and inspect retention, continuity and isolation before service. Wire color alone does not establish the circuit assignment.\u003c\/p\u003e\n\u003ch3\u003eIncluded in each set\u003c\/h3\u003e\n\u003cp\u003eOne male half and one matching female half, with integral contacts and the pictured fastening parts. No loose crimp terminals, cable, solder, tools or equipment are supplied.\u003c\/p\u003e\n\u003ch3\u003eComplete your matching parts\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"\/collections\/xs10-family\"\u003eBrowse XS10 connector sets by mounting style and contact count\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003c\/div\u003e\u003cdiv class=\"pevxi-order-heading\" id=\"pevxi-bulk\"\u003e\n\u003ch2\u003eBuild your order, pack by pack.\u003c\/h2\u003e\n\u003cp\u003eEvery row below is the same 4-pin cable-to-cable set. The selected pack contains 1, 5 or 20 complete sets; quantity counts packs.\u003c\/p\u003e\n\u003cp\u003eShips from China · Preparation 5–7 calendar days. \u003ca href=\"\/policies\/shipping-policy\"\u003eShipping details\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"PEVXI","offers":[{"title":"1 Set","offer_id":50983657603330,"sku":"XS10-4-D-1","price":7.0,"currency_code":"USD","in_stock":true},{"title":"5 Sets - Save 5%","offer_id":50983657636098,"sku":"XS10-4-D-5","price":33.25,"currency_code":"USD","in_stock":true},{"title":"20 Sets - Save 10%","offer_id":50983657668866,"sku":"XS10-4-D-20","price":126.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-f8a89e1f8a4b20-01-hero.jpg?v=1794265948"},{"product_id":"xs10-5-connector-set","title":"5-Pin XS10 Panel \u0026 Cable Push-Pull Connector Set","description":"\u003cdiv class=\"pevxi-story\"\u003e\n\u003cnav class=\"pevxi-story-nav\"\u003e\u003ca href=\"#pevxi-applications\"\u003eApplications\u003c\/a\u003e\u003ca href=\"#pevxi-size\"\u003eSpecifications\u003c\/a\u003e\u003ca href=\"#pevxi-workflow\"\u003eInstallation\u003c\/a\u003e\u003ca href=\"#pevxi-bulk\"\u003eQuick order\u003c\/a\u003e\u003c\/nav\u003e\u003csection id=\"pevxi-applications\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-ef716af2e129e9-04-application.jpg?v=1794240381\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-5 04-application\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e5-Pin XS10 Panel \u0026amp; Cable Push-Pull Connector Set\u003c\/h2\u003e\n\u003cp\u003eOne complete matching male and female set, fixed at 5 contacts. Includes a male panel receptacle and a female cable connector.\u003c\/p\u003e\n\u003cp\u003eFor instrument wiring, serviceable equipment leads and compact test fixtures. Match contact count, mounting structure, alignment key and circuit assignment before connecting.\u003c\/p\u003e\n\u003cp\u003eChoose 1, 5 or 20 sets per pack. Other contact counts and mounting styles are separate products.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"pevxi-size\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\n\u003ch2\u003eInterface \u0026amp; specifications\u003c\/h2\u003e\n\u003ctable class=\"pevxi-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eXS10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContact count\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003ctd\u003ePanel-to-cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTermination\u003c\/th\u003e\n\u003ctd\u003eIntegral solder contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal interface\u003c\/th\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier reference outline\u003c\/th\u003e\n\u003ctd\u003e31.5 mm body section; 9.5 mm panel projection; M10 mounting thread. See the original outline for measurement boundaries.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier rating reference\u003c\/th\u003e\n\u003ctd\u003e3 A \/ 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier test voltage reference\u003c\/th\u003e\n\u003ctd\u003e2000 V AC \/ 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier insulation resistance\u003c\/th\u003e\n\u003ctd\u003eAt least 1000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier contact resistance\u003c\/th\u003e\n\u003ctd\u003eAt most 0.005 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSupplier reference values are connector data, not a certification of the complete equipment or a wired assembly.\u003c\/p\u003e\n\u003ch3\u003eModel \u0026amp; Reference Codes\u003c\/h3\u003e\n\u003ctable class=\"pevxi-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSet SKU\u003c\/th\u003e\n\u003ctd\u003eXS10-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMale half\u003c\/th\u003e\n\u003ctd\u003eXS10-5-M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFemale half\u003c\/th\u003e\n\u003ctd\u003eXS10-5-F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-73a0414a8ccfd3-02-size.jpg?v=1794238453\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-5 02-size\"\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"pevxi-workflow\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-c2d9a077f74d19-05-operation.jpg?v=1794240740\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-5 05-operation\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003ePrepare. Solder. Inspect.\u003c\/h2\u003e\n\u003cp\u003eWork on de-energized circuits. Slide the cable housing and fastening parts onto the cable before termination. Solder the conductors to their assigned contacts and insulate the joints.\u003c\/p\u003e\n\u003cp\u003eRefit the housing and cable fastening parts. Align the key, mate fully and inspect retention, continuity and isolation before service. Wire color alone does not establish the circuit assignment.\u003c\/p\u003e\n\u003ch3\u003eIncluded in each set\u003c\/h3\u003e\n\u003cp\u003eOne male half and one matching female half, with integral contacts and the pictured fastening parts. No loose crimp terminals, cable, solder, tools or equipment are supplied.\u003c\/p\u003e\n\u003ch3\u003eComplete your matching parts\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"\/collections\/xs10-family\"\u003eBrowse XS10 connector sets by mounting style and contact count\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003c\/div\u003e\u003cdiv class=\"pevxi-order-heading\" id=\"pevxi-bulk\"\u003e\n\u003ch2\u003eBuild your order, pack by pack.\u003c\/h2\u003e\n\u003cp\u003eEvery row below is the same 5-pin panel-to-cable set. The selected pack contains 1, 5 or 20 complete sets; quantity counts packs.\u003c\/p\u003e\n\u003cp\u003eShips from China · Preparation 5–7 calendar days. \u003ca href=\"\/policies\/shipping-policy\"\u003eShipping details\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"PEVXI","offers":[{"title":"1 Set","offer_id":50983658193154,"sku":"XS10-5-1","price":5.6,"currency_code":"USD","in_stock":true},{"title":"5 Sets - Save 5%","offer_id":50983658225922,"sku":"XS10-5-5","price":26.6,"currency_code":"USD","in_stock":true},{"title":"20 Sets - Save 10%","offer_id":50983658258690,"sku":"XS10-5-20","price":100.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-f8c45d0c375856-01-hero.jpg?v=1794265955"},{"product_id":"xs10-5-d-connector-set","title":"5-Pin XS10 Cable-to-Cable Push-Pull Connector Set","description":"\u003cdiv class=\"pevxi-story\"\u003e\n\u003cnav class=\"pevxi-story-nav\"\u003e\u003ca href=\"#pevxi-applications\"\u003eApplications\u003c\/a\u003e\u003ca href=\"#pevxi-size\"\u003eSpecifications\u003c\/a\u003e\u003ca href=\"#pevxi-workflow\"\u003eInstallation\u003c\/a\u003e\u003ca href=\"#pevxi-bulk\"\u003eQuick order\u003c\/a\u003e\u003c\/nav\u003e\u003csection id=\"pevxi-applications\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-9655870e65d1e8-04-application.jpg?v=1794240393\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-5-D 04-application\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e5-Pin XS10 Cable-to-Cable Push-Pull Connector Set\u003c\/h2\u003e\n\u003cp\u003eOne complete matching male and female set, fixed at 5 contacts. Both halves are cable connectors for an inline cable connection.\u003c\/p\u003e\n\u003cp\u003eFor instrument wiring, serviceable equipment leads and compact test fixtures. Match contact count, mounting structure, alignment key and circuit assignment before connecting.\u003c\/p\u003e\n\u003cp\u003eChoose 1, 5 or 20 sets per pack. Other contact counts and mounting styles are separate products.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"pevxi-size\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\n\u003ch2\u003eInterface \u0026amp; specifications\u003c\/h2\u003e\n\u003ctable class=\"pevxi-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eXS10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContact count\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003ctd\u003eCable-to-cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTermination\u003c\/th\u003e\n\u003ctd\u003eIntegral solder contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal interface\u003c\/th\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier rating reference\u003c\/th\u003e\n\u003ctd\u003e3 A \/ 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier test voltage reference\u003c\/th\u003e\n\u003ctd\u003e2000 V AC \/ 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier insulation resistance\u003c\/th\u003e\n\u003ctd\u003eAt least 1000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier contact resistance\u003c\/th\u003e\n\u003ctd\u003eAt most 0.005 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSupplier reference values are connector data, not a certification of the complete equipment or a wired assembly.\u003c\/p\u003e\n\u003ch3\u003eModel \u0026amp; Reference Codes\u003c\/h3\u003e\n\u003ctable class=\"pevxi-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSet SKU\u003c\/th\u003e\n\u003ctd\u003eXS10-5-D-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMale half\u003c\/th\u003e\n\u003ctd\u003eXS10-5-M-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFemale half\u003c\/th\u003e\n\u003ctd\u003eXS10-5-F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-c8cc8ba28911eb-02-size.jpg?v=1794238453\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-5-D 02-size\"\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"pevxi-workflow\" class=\"pevxi-story-section pevxi-story-grid\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-dc642d65f3db32-05-operation.jpg?v=1794240747\" width=\"1200\" height=\"1200\" loading=\"lazy\" alt=\"XS10-5-D 05-operation\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003ePrepare. Solder. Inspect.\u003c\/h2\u003e\n\u003cp\u003eWork on de-energized circuits. Slide the cable housing and fastening parts onto the cable before termination. Solder the conductors to their assigned contacts and insulate the joints.\u003c\/p\u003e\n\u003cp\u003eRefit the housing and cable fastening parts. Align the key, mate fully and inspect retention, continuity and isolation before service. Wire color alone does not establish the circuit assignment.\u003c\/p\u003e\n\u003ch3\u003eIncluded in each set\u003c\/h3\u003e\n\u003cp\u003eOne male half and one matching female half, with integral contacts and the pictured fastening parts. No loose crimp terminals, cable, solder, tools or equipment are supplied.\u003c\/p\u003e\n\u003ch3\u003eComplete your matching parts\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"\/collections\/xs10-family\"\u003eBrowse XS10 connector sets by mounting style and contact count\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003c\/div\u003e\u003cdiv class=\"pevxi-order-heading\" id=\"pevxi-bulk\"\u003e\n\u003ch2\u003eBuild your order, pack by pack.\u003c\/h2\u003e\n\u003cp\u003eEvery row below is the same 5-pin cable-to-cable set. The selected pack contains 1, 5 or 20 complete sets; quantity counts packs.\u003c\/p\u003e\n\u003cp\u003eShips from China · Preparation 5–7 calendar days. \u003ca href=\"\/policies\/shipping-policy\"\u003eShipping details\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"PEVXI","offers":[{"title":"1 Set","offer_id":50983658488066,"sku":"XS10-5-D-1","price":7.0,"currency_code":"USD","in_stock":true},{"title":"5 Sets - Save 5%","offer_id":50983658520834,"sku":"XS10-5-D-5","price":33.25,"currency_code":"USD","in_stock":true},{"title":"20 Sets - Save 10%","offer_id":50983658553602,"sku":"XS10-5-D-20","price":126.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-xs10-a49f1d917d1a2c-01-hero.jpg?v=1794265962"}],"url":"https:\/\/pevxi.com\/collections\/xs10-family.oembed","provider":"PEVXI","version":"1.0","type":"link"}