{"product_id":"gx12-4-m-d-connector","title":"GX12-4 Inline Male Cable Solder Connector","description":"\u003cdiv class=\"pevxi-story\"\u003e\n\u003cnav class=\"pevxi-story-nav\"\u003e\u003ca href=\"#pevxi-applications\"\u003eApplications\u003c\/a\u003e\u003ca href=\"#pevxi-size\"\u003eSize \u0026amp; specifications\u003c\/a\u003e\u003ca href=\"#pevxi-electrical\"\u003eElectrical specifications\u003c\/a\u003e\u003ca href=\"#pevxi-workflow\"\u003eHow it is used\u003c\/a\u003e\u003ca href=\"#pevxi-bulk\"\u003eQuick order\u003c\/a\u003e\u003c\/nav\u003e\u003csection class=\"pevxi-story-section pevxi-story-grid\" id=\"pevxi-applications\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-ecu-0654629f4293c6-04-application.jpg?v=1793947578\" alt=\"Equipment and cable applications\" width=\"1200\" height=\"1200\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003eGX12-4 Inline Male Cable Solder Connector\u003c\/h2\u003e\n\u003cp\u003eFor compatible cable-to-cable harness connections. Match the position count, contact gender, key and actual mounting or cable configuration.\u003c\/p\u003e\n\u003ch3\u003eIncluded in one sales unit\u003c\/h3\u003e\n\u003cp\u003e1 complete inline male connector unit with insert, threaded rear cover and cable clamp\u003c\/p\u003e\n\u003ctable class=\"pevxi-spec-table\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003cth\u003einline male connector unit [GX12-4-M-D]\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eGeneric industry style; comparison geometry does not identify original-brand supply or verified electrical ratings. Cable and tools are excluded unless listed as part of the assembled cable unit. A separate mating half is included only when listed above.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection class=\"pevxi-story-section pevxi-story-grid\" id=\"pevxi-size\"\u003e\u003cdiv\u003e\n\u003ch2\u003eModel \u0026amp; Reference Codes\u003c\/h2\u003e\n\u003ctable class=\"pevxi-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOriginal single-unit SKU\u003c\/th\u003e\n\u003ctd\u003eGX12-4-M-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIndustry model\u003c\/th\u003e\n\u003ctd\u003eGX12-4 style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003ctd\u003eInline Male Cable Solder Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePositions at each connector\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSales unit\u003c\/th\u003e\n\u003ctd\u003e1 complete inline male connector unit with insert, threaded rear cover and cable clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit weight\u003c\/th\u003e\n\u003ctd\u003e0.0181 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTermination\u003c\/th\u003e\n\u003ctd\u003eIntegrated solder-cup contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. supplier separate component lengths\u003c\/th\u003e\n\u003ctd\u003eMale insert20.5mm; docking rear cover31mm. These lengths overlap after assembly and are not added.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference outline\u003c\/th\u003e\n\u003ctd\u003eSeries reference geometry; not a supplied-unit measurement or an electrical rating.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-gx12-dd03d01abc470d-47776956252418-02-technical.jpg?v=1793959919\" alt=\"Actual configuration and size or fit reference\" width=\"1200\" height=\"1200\" loading=\"lazy\"\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection class=\"pevxi-story-section\" id=\"pevxi-electrical\"\u003e\u003ch2\u003eElectrical specifications\u003c\/h2\u003e\n\u003cp\u003eGX12 connector reference specifications. Match the selected position count and the requirements of the equipment.\u003c\/p\u003e\n\u003ctable class=\"pevxi-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePositions\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated current \/ voltage\u003c\/th\u003e\n\u003ctd\u003e5 A \/ 125 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorking voltage (AC Vrms)\u003c\/th\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWithstand voltage (AC Vrms)\u003c\/th\u003e\n\u003ctd\u003e1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInsulation impedance\u003c\/th\u003e\n\u003ctd\u003e1500 — unit not specified in the reference table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eContact resistance\u003c\/th\u003e\n\u003ctd\u003e5 — unit not specified in the reference table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSolder cup hole diameter\u003c\/th\u003e\n\u003ctd\u003e0.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePin \/ hole diameter\u003c\/th\u003e\n\u003ctd\u003eØ1.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/section\u003e\u003csection class=\"pevxi-story-section pevxi-story-grid\" id=\"pevxi-workflow\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-ecu-fcfab21e203442-05-operation.jpg?v=1793947578\" alt=\"Installation and inspection\" width=\"1200\" height=\"1200\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003eConnect and inspect\u003c\/h2\u003e\n\u003cp\u003eDisconnect power and follow the equipment wiring diagram.\u003c\/p\u003e\n\u003cp\u003eRoute cable through the rear cover before soldering. Use a soldering process suitable for the actual contacts and wire. Inspect for bridges, insulate joints, close and retain the cable at its clamp, then align and mate without forcing.\u003c\/p\u003e\n\u003ch3\u003ePack quantities\u003c\/h3\u003e\n\u003cp\u003eSelect 1 \/ 5 \/ 20 connectors per pack. Quantity counts packs; physical units equal packs multiplied by pack size. Pack totals already include the displayed discount.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003c\/div\u003e\u003cdiv class=\"pevxi-order-heading\" id=\"pevxi-bulk\"\u003e\n\u003ch2\u003eBuild your order, pack by pack.\u003c\/h2\u003e\n\u003cp\u003eThe complete shipping SKU, pack size and total appear in each row.\u003c\/p\u003e\n\u003cp\u003eShips from China · 5–7 calendar days preparation. \u003ca href=\"\/policies\/shipping-policy\"\u003eShipping\u003c\/a\u003e · \u003ca href=\"\/policies\/refund-policy\"\u003eReturns\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"PEVXI","offers":[{"title":"1 Connector","offer_id":50977237827842,"sku":"GX12-4-M-D","price":2.21,"currency_code":"USD","in_stock":true},{"title":"5 Connectors - Save 5%","offer_id":50977237860610,"sku":"GX12-4-M-D-5","price":10.5,"currency_code":"USD","in_stock":true},{"title":"20 Connectors - Save 10%","offer_id":50977237893378,"sku":"GX12-4-M-D-20","price":39.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-ecu-6b5a34ac3ca7e2-01-hero.jpg?v=1793947578","url":"https:\/\/pevxi.com\/products\/gx12-4-m-d-connector","provider":"PEVXI","version":"1.0","type":"link"}