{"product_id":"sp13-2-fl-f-m-connector","title":"2-Pin SP13 Two-Hole Flange Connector Set","description":"\u003cdiv class=\"pevxi-story\"\u003e\n\u003cnav class=\"pevxi-story-nav\"\u003e\u003ca href=\"#pevxi-applications\"\u003eApplications\u003c\/a\u003e\u003ca href=\"#pevxi-size\"\u003eModel \u0026amp; specifications\u003c\/a\u003e\u003ca href=\"#pevxi-workflow\"\u003eAssembly\u003c\/a\u003e\u003ca href=\"#pevxi-bulk\"\u003eQuick order\u003c\/a\u003e\u003c\/nav\u003e\u003csection class=\"pevxi-story-section pevxi-story-grid\" id=\"pevxi-applications\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-sp13-c7f62ded0b8361-04-application.jpg?v=1794018268\" alt=\"Original SP13 flange series workshop\/application reference; equipment, screws and wire not supplied\" width=\"1200\" height=\"1200\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e2-Pin SP13 Two-Hole Flange Connector Set\u003c\/h2\u003e\n\u003cp\u003eCreate a detachable panel-to-cable connection for control panels, lighting equipment and signal interfaces. The two-hole flange secures the panel half; the straight cable connector couples to the matching keyed interface.\u003c\/p\u003e\n\u003ch3\u003eOne complete sales unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Cable connector — SP13-GT-2\u003c\/li\u003e\n\u003cli\u003e1 x Two-hole flange panel connector with retaining cap as shown — SP13-FL-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRetaining cap as shown in the product image. Contacts are integral to the supplied connectors; no separate crimp terminals are added. Panel, mounting screws, cable, solder and tools are sold separately.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection class=\"pevxi-story-section pevxi-story-grid\" id=\"pevxi-size\"\u003e\u003cdiv\u003e\n\u003ch2\u003eModel \u0026amp; Reference Codes\u003c\/h2\u003e\n\u003ctable class=\"pevxi-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping set SKU\u003c\/th\u003e\n\u003ctd\u003eSP13-2P-FL-F-M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIndustry series\u003c\/th\u003e\n\u003ctd\u003eSP13-style two-hole flange panel \/ cable connector pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContact positions\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIndustry family references\u003c\/th\u003e\n\u003ctd\u003eSP1310 cable connector; SP1313 two-hole flange panel socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference scope\u003c\/th\u003e\n\u003ctd\u003eFamily style references only; generic supply, not original-brand parts or an exact OEM ordering suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTermination\u003c\/th\u003e\n\u003ctd\u003eIntegral solder contacts; wire and solder not supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eTwo-hole flange panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplier model\u003c\/th\u003e\n\u003ctd\u003eSP13-2F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePanel cutout reference\u003c\/th\u003e\n\u003ctd\u003eRound13 mm central opening; two3.5 mm screw holes;22.1 mm centres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCable body reference length\u003c\/th\u003e\n\u003ctd\u003e49 mm (supplier outline; not warehouse measurement)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlange body reference length\u003c\/th\u003e\n\u003ctd\u003e18.5 mm (supplier side outline)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCable jacket outside diameter\u003c\/th\u003e\n\u003ctd\u003e4-6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSales unit\u003c\/th\u003e\n\u003ctd\u003e1 two-hole flange panel connector and 1 matching cable connector; retaining cap as shown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit weight\u003c\/th\u003e\n\u003ctd\u003e15.3 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current reference\u003c\/th\u003e\n\u003ctd\u003e13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWorking voltage reference\u003c\/th\u003e\n\u003ctd\u003e250 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTest voltage reference\u003c\/th\u003e\n\u003ctd\u003e1500 V AC \/1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContact diameter reference\u003c\/th\u003e\n\u003ctd\u003e1.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConductor size reference\u003c\/th\u003e\n\u003ctd\u003eup to2 mm2 \/14 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eUse the supplied interface, pin count and key position to select the pair. Supplier reference dimensions and electrical values describe the pictured configuration and do not establish third-party certification or original-brand supply. Cable choice, termination and equipment conditions also determine operating limits.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-sp13-3d7dc1e68e5f32-02-size.jpg?v=1794018268\" alt=\"Original same-SKU mating views, dimensions and confirmed reference specifications\" width=\"1200\" height=\"1200\" loading=\"lazy\"\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection class=\"pevxi-story-section pevxi-story-grid\" id=\"pevxi-workflow\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-sp13-fbe867414dac3a-05-operation.jpg?v=1794018268\" alt=\"Cable gland preparation, solder termination, panel installation and mating checks\" width=\"1200\" height=\"1200\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003ePrepare, terminate and inspect\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eFit the gland parts to a correctly sized cable before soldering.\u003c\/li\u003e\n\u003cli\u003eFollow the actual marked contact positions and check continuity and shorts.\u003c\/li\u003e\n\u003cli\u003eCheck the actual two-hole pattern and seat the flange seal. Supply suitable mounting screws separately; secure the cable gland without forcing.\u003c\/li\u003e\n\u003cli\u003eAlign the keyed faces and mate the matching contact count. Tighten the coupling by hand.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eChoose complete sets per pack\u003c\/h3\u003e\n\u003cp\u003eSelect 1\/5\/20 sets per pack. The order quantity counts packs. Physical connector sets equal pack count multiplied by the selected pack size; the displayed pack price includes the shown discount.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003c\/div\u003e\u003cdiv class=\"pevxi-order-heading\" id=\"pevxi-bulk\"\u003e\n\u003ch2\u003eBuild your order, pack by pack.\u003c\/h2\u003e\n\u003cp\u003eCompare the complete shipping SKU, pack size and total in each row.\u003c\/p\u003e\n\u003cp\u003eShips from China · 5–7 calendar days preparation. \u003ca href=\"\/policies\/shipping-policy\"\u003eShipping\u003c\/a\u003e · \u003ca href=\"\/policies\/refund-policy\"\u003eReturns\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"PEVXI","offers":[{"title":"1 Set","offer_id":50983140458754,"sku":"SP13-2P-FL-F-M","price":8.93,"currency_code":"USD","in_stock":true},{"title":"5 Sets - Save 5%","offer_id":50983140491522,"sku":"SP13-2P-FL-F-M-5","price":42.42,"currency_code":"USD","in_stock":true},{"title":"20 Sets - Save 10%","offer_id":50983140524290,"sku":"SP13-2P-FL-F-M-20","price":160.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/3282\/9186\/files\/pevxi-sp13-4d87ca93d76fa8-01-hero.jpg?v=1794018268","url":"https:\/\/pevxi.com\/products\/sp13-2-fl-f-m-connector","provider":"PEVXI","version":"1.0","type":"link"}